TCRT

TCRT Controladores Temperatura Bru y Rubio

ZonesLBHKgs.DESC.COD.
1232028048630TCRT-1243794
2432038073448TCRT-2443748
3637055085276TCRT-3643796
48436.555091098TCRT-4843797
64436.55501228112TCRT-64TCRT-64
72486.55501228132TCRT-72TCRT-72
96579.55831241184TCRT-96TCRT-96
1206185831360220TCRT-120TCRT-120
FUNCTIONS:

– Ambient Temperature: 32ºF to 131ºF (0ºC to 55ºC) Relative Humidity: 10% -95%.
– Delivery Temperature: -40 ºF to 158 ºF (-40 ºC to 70 ºC)
– Power Supply: AC185V-245V, 50 / 60HZ
– T/C Type: J/K
– Temperature unit: ºC / ºF
– Temperature control range: 45 ºC to 550 ºC
– Temperature test accuracy: + 3%.
– Repeated temperature measurement accuracy: + 0.1%.
– Stable temperature accuracy: + 0.5%.
– T / C cooling compensation: dynamic tracking
– Noise restriction: Common mode rejection ratio > 100 dB, sampling frequency: 10 HZ (100 mS).
– Single point load: 15A
– F1, F2, F3, F4: 250V-15A (special fuse)
– With FUZZY PIDD control technology, when PID parameters are not set, it can automatically adapt to any heating model and greatly improve the working efficiency.
– To avoid the influence of ambient temperature during measurement.
Use of inner and outer ring for dynamic ambient temperature monitoring. Cold compensation with outer ring thermistor, dynamic elimination of environmental influence to the measuring circuit by precision voltage of inner ring, make the control measurement more accurate.
– The controller can easily detect inverted T/C or open T/C, and will operate according to the error information and control mode when the problems are detected.
– Heater current monitor
– Soft start function
– Temperature deviation alarms.
– Manual output mode
– Non-touch transfer
– General error indicator, easy to find reason for error
– Output module rating 15 A per point
– Simple, intuitive and humanized operating interface
– Plug-in module design for easy maintenance;
– External radiator for high efficiency dissipation heater.

 

 

 

 

TCRT- Bru y Rubio

Add to basket by clicking on DESC.